Service Tubing
Service tubing is a flexible pipe that carries potable water from a water main to a building, connecting the corporation stop, curb stop, and meter along the way. It is commonly sized from 3/4 in through 2 in and installed underground on municipal, residential, and rural water service lines. This category covers polyethylene water service tubing made from PE4710 resin, manufactured to copper tube size (CTS) or iron pipe size (IPS) outside diameters. CTS tubing rated SDR 9 carries a 250 psi pressure rating and fits the same compression fittings used with Type K copper when insert stiffeners are installed. Coils install in long continuous runs with fewer joints than rigid pipe, which reduces leak points below grade. Use the sections below to compare product groups, standards, and sizing.
Service Tubing
Service Tubing Products
Polyflex Pressure Pipe
Polyflex pressure pipe is a flexible polyethylene line built for water service, potable water, agricultural, and landscape irrigation applications. The line includes potable CTS tubing, potable IPS pipe, and utility grade IPS pipe. Coils unroll for long trench, plow, or pull installations with few joints. Browse Polyflex Pressure Pipe to compare sizes, coil lengths, and pressure ratings of tubing for water supply systems.
Potable CTS Water Service Tubing
Potable CTS water service tubing is made from PE4710 high-density polyethylene and rated SDR 9 at 250 psi. Its outside diameter matches copper tube size, so it connects to standard CTS compression fittings. Common sizes run from 3/4 in through 2 in, and potable tubing is typically blue for line identification.
Potable IPS Pressure Pipe
Potable IPS pipe follows iron pipe size outside diameters and is certified to NSF/ANSI 14 and 61 for drinking water. IPS pipe uses IPS fittings, not CTS fittings, so the two size systems cannot be mixed without a transition fitting.
Utility Grade Pressure Pipe
Utility grade IPS pipe is built for non-potable lines, including agricultural water, landscape irrigation, slurry lines, and residential or commercial irrigation systems. Drinking water lines require a pipe with an NSF/ANSI 61 mark on the print line.
Connections and Insert Stiffeners
Polyethylene tubing connects through compression or pack-joint fittings at the corporation stop, curb stop, and meter setter. An insert stiffener goes inside the tubing at each joint to keep the wall from collapsing under fitting pressure. Compatible couplings and adapters are listed under Service & Repair Fittings.
How It Works and Where to Use It
How Service Tubing Carries Water
Water leaves the main through a corporation stop tapped into the pipe or a service saddle. The tubing runs underground to a curb stop, which shuts off the line near the property line, then continues to the meter setter and into the building. Fittings at each point connect and seal the tubing.
Municipal and Residential Water Service
Utilities and contractors use underground water service tubing for new taps, service renewals, and replacement of lead or galvanized lines. In residential work, the tubing serves as water distribution tubing from the meter to the building wall.
Wells, Farms, and Rural Lines
Outside municipal systems, polyethylene water supply tubing connects well pumps to pressure tanks and houses, and supplies livestock waterers and outbuildings on farm and ranch properties. Coil lengths reduce the number of joints on long rural runs.
Direct Bury, Plowing, and Pulling
Polyethylene service tubing can be directly buried in an open trench, plowed in, or pulled into place, following local, state, or federal guidelines. Before burying, confirm the required depth below the frost line with the local code authority, bed the tubing in sand or fine soil free of rocks, and leave slack for soil movement.
Key Specifications and Planning Steps
Standards and Certifications
Potable water service tubing is manufactured to ASTM D2737 and AWWA C901, the AWWA standard for polyethylene pressure pipe and tubing in water service, and is certified to NSF/ANSI 14 and 61 for drinking water contact. Confirm Build America, Buy America (BABA) compliance for federally funded projects.
Pressure Class and Sizing
PE4710 is the resin designation for high-density polyethylene. SDR 9 means the outside diameter is nine times the wall thickness, which gives CTS tubing a 250 psi rating. In water service piping, CTS and IPS outside diameters differ at the same nominal size.
Print Line and Color Coding
The print line shows nominal size, SDR, pressure rating, resin code, standards, and certification marks, with footage marks along the coil. Blue commonly identifies potable water tubing; lavender identifies reclaimed water lines.
Before Installation
Disinfect new and repaired lines following ANSI/AWWA C651, flush all disinfecting solutions, confirm local code approval, and match each fitting to the tubing size system.
Choosing the Right Service Tubing
Match service tubing to the valve and fitting size system: CTS tubing to CTS fittings, IPS pipe to IPS fittings, with a transition fitting where the two meet. Choose 3/4 in or 1 in based on fixture demand, run length, supply pressure, elevation change, and the minimum size set by local code or the water utility. Select potable-rated tubing for any line that supplies drinking water, and reserve utility grade pipe for irrigation and other non-potable uses. Compared with Type K copper, polyethylene water service line tubing resists corrosion and comes in longer coils with fewer joints. Check approved materials with the local authority, and pair the tubing with compatible water service line products such as curb stops and meter setters.
Frequently Asked Questions
Where can I buy 1 inch CTS polyethylene water service tubing in a 100 ft or 500 ft coil?
The Polyflex pressure pipe line includes potable CTS tubing in sizes from 3/4 in through 2 in, including 1 in. Coil lengths such as 100 ft and 500 ft are common for this tubing; check the listings in this category for the lengths currently available.
What service tubing should I order for a new 3/4 inch water service from the meter to the house?
Order 3/4 in CTS polyethylene tubing rated SDR 9 (250 psi) with an NSF/ANSI 61 mark, plus CTS compression fittings and insert stiffeners. Confirm the minimum service size with the local water utility or code authority before ordering.
What is the difference between CTS and IPS polyethylene pipe for a water service line?
CTS tubing matches copper tube outside diameters and connects to CTS valves and fittings. IPS pipe matches iron pipe outside diameters. At the same nominal size the outside diameters differ, so the fittings are not interchangeable without a transition fitting.
What are the advantages of polyethylene service tubing over Type K copper for a buried water service line?
Polyethylene resists corrosion, does not add dissolved metals to drinking water, and comes in long coils that reduce buried joints. It also weighs less to handle on the jobsite. Some utilities still specify copper, so confirm approved materials locally.
Is SDR 9 PE4710 tubing rated high enough for municipal water service?
Yes, for most services. SDR 9 PE4710 CTS tubing carries a 250 psi pressure rating and is manufactured to AWWA C901, the standard for polyethylene water service tubing. Check the utility's specification for any required pressure class.
Do I need to insert stiffeners when connecting polyethylene water service tubing to compression fittings?
Yes. Install an insert stiffener at every compression or pack-joint connection on polyethylene tubing. The stiffener supports the tubing wall so the fitting grips and seals without collapsing the pipe.
What should I check before burying polyethylene water service tubing?
Confirm the required burial depth below the frost line with the local code authority, prepare bedding free of rocks, avoid kinks, and leave slack for soil movement. After installation, pressure test the line and disinfect it per ANSI/AWWA C651.
My inspector wants an NSF 61 certified water line. How do I check if my service tubing meets it?
Read the print line on the tubing. Potable tubing carries an NSF/ANSI 61 mark (often shown with an NSF-pw or NSF-61 marking) along with ASTM D2737 and AWWA C901. The manufacturer's spec sheet lists the same certifications.
Can polyethylene CTS service tubing use the same compression fittings as Type K copper?
Yes. CTS polyethylene tubing shares the copper tube size outside diameter, so CTS compression and pack-joint fittings are designed to fit both. Polyethylene requires an insert stiffener at each joint; check the fitting manufacturer's listing for approved tubing types.
What markings should I look for on water service tubing before I install it?
Check for nominal size, CTS or IPS designation, SDR, pressure rating, PE4710 resin code, ASTM D2737, AWWA C901, NSF/ANSI 61, and manufacturer information. Footage marks along the coil help measure the run.
Should I use 3/4 inch or 1 inch water service tubing, and what factors decide the size?
Size depends on fixture demand, run length, supply pressure at the main, elevation change, and any irrigation load. Local code or the water utility also sets a minimum service size. Longer runs and higher demand often call for 1 in.
Can I pull or plow in polyethylene water service tubing instead of open trenching?
Yes. Manufacturer specifications list direct bury, plowing, and pulling as accepted installation methods for polyethylene water service tubing, applied according to local, state, or federal guidelines.
What does the blue color on water service tubing mean, and what is lavender tubing used for?
Blue commonly identifies tubing for potable water service. Lavender identifies reclaimed water lines, which carry treated non-potable water and must not be connected to drinking water systems.
What fittings connect polyethylene water service tubing to the corporation stop and the curb stop?
CTS compression or pack-joint connections on the outlet of the corporation stop and on both ends of the curb stop, each with an insert stiffener. Use a transition coupling where new tubing meets existing copper or IPS pipe.
Is polyethylene service tubing safe for drinking water and approved under AWWA C901?
Yes, when it is potable rated. Potable water service piping made from PE4710 is manufactured to AWWA C901 and certified to NSF/ANSI 61 for drinking water contact. Disinfect new lines per ANSI/AWWA C651 before service.